Handicare C Series Patient Lift Product Usage: A device used to lift and transport a patient recall — FDA Z-2752-2018
Premature strap wear and breakage at maximum weight conditions (625 lbs.).
Browse the newest complete recall records currently stored from FDA enforcement reports and NHTSA vehicle campaigns. “Latest” refers to the newest source-dated record in this database, not the timestamp of our last API check.
The newest recall records with useful source details are listed here.
Premature strap wear and breakage at maximum weight conditions (625 lbs.).
GE Healthcare has identified that some CT systems may have a damaged cable that can expose 120VAC to Service Engineers working inside the gantry.
In rare cases of insufficient maintenance or high clinical workload, the first rope of the ceiling stand, which is designed to take the load, could break without triggering the safety lock…
This email is to provide notification that, due to a software bug that has been corrected, the Radiological Read Report for the VMA test(s) contained an error.
A portion of this lot was manufactured using Gentamicin instead of Vancomycin. Gentamicin is an inhibitory agent of Neisseria organisms. This product is a selective plated medium to provide…
The firm received a complaint where, during patient positioning, the technologist was adjusting the patient table height and the table failed to stop when the control was released and…
Ortho Kinematics notified customers that errors were contained in Radiological Read Report and VMA Report for the VMA test. The error resulted from an administrative error of VMA user…
One lot of product is from product code AK-22502 so it contains a 2-lumen, 5 Fr x 5 cm catheter. However, this product is incorrectly labeled as AK-25502, so the lidstock says it contains a…
Incorrectly labeled Manufactured by DiaSorin, The correct term should be Distributed by DiaSorin.
Johnson and Johnson Vision Care received a number of reports of a partially formed contact lens, which appears to the customer or consumer as visibly smaller in diameter, thicker/stiffer to…
A May 2015 design change in the cushion seal replacement part and accompanying elbow replacement part resulted in incompatibility of the new cushion seal with the previous design of the…
In rare cases of insufficient maintenance or high clinical workload, the first rope of the ceiling stand, which is designed to take the load, could break without triggering the safety lock…
Incorrectly labeled Manufactured by DiaSorin, The correct term should be Distributed by DiaSorin.
Incorrectly labeled Manufactured by DiaSorin, The correct term should be Distributed by DiaSorin.
GE Healthcare has identified that some CT systems may have a damaged cable that can expose 120VAC to Service Engineers working inside the gantry.
The PPK System Spacer Block Alignment Tower mating feature that mates with the spacer block was undersized, which could potentially lead to mating issues between the devices. This could…
Philips has received several reports in which monitors with lithium ion batteries that had exceeded their battery life expectancy have overheated or ignited. These batteries should be…
Customer reports indicated an increase in the rate of non-detected MRSA in association with the VITEK 2 AST-P631 product.
There is a potential for an uncontrolled extension of iViewGT / XVI detector arms.
Packages labeled as containing 110mm rods may contain 100mm rods.
Two instrument holes located on the side of the plate, which act to align the saw guide are located on the wrong side of the plate
Philips has received several reports in which monitors with lithium ion batteries that had exceeded their battery life expectancy have overheated or ignited. These batteries should be…
Philips has received several reports in which monitors with lithium ion batteries that had exceeded their battery life expectancy have overheated or ignited. These batteries should be…
A cover failed leak testing during validation testing of new needle guides from a replacement tool.