FDA recall record

Ortho-Clinical Diagnostics VITROS CHEMISTRY PRODUCTS TRIG Slides, REF 133 6544, IVD For in recall — FDA Z-0848-2015

Potential for biased results using the specific lot of VITROS CHEMISTRY PRODUCTS TRIG slides.

Class IIclassification
Z-0848-2015official record ID
Dec 31, 2014report date

Recall record at a glance

Official recordZ-0848-2015
CategoryMedical Device Recalls
ClassificationClass II
FDA record statusTerminated
Recalling firmOrtho-Clinical Diagnostics
Report dateDec 31, 2014
Recall initiation dateNov 6, 2014
QuantityUSA: 380 units, Foreign: 155 units
LocationRochester, NY, United States

Official product description

VITROS CHEMISTRY PRODUCTS TRIG Slides, REF 133 6544, IVD For in vitro diagnostic use only. VITROS Chemistry Products TRIG Slides quantitatively measure triglyceride (TRIG) concentration in serum and plasma using VITROS 250/350/950/5,1 FS and 4600 Chemistry Systems and the VITROS 5600 Integrated System.

Why the product was recalled

Potential for biased results using the specific lot of VITROS CHEMISTRY PRODUCTS TRIG slides.

Distribution information

Worldwide Distribution - USA (nationwide) Puerto Rico and Internationally to Australia, Brazil, Canada, Chile, China, Colombia, England, France, Germany, India, Italy, Japan, Mexico, Panama, Singapore, Spain and Venezuela.

How to read the classification

FDA Class II indicates a situation in which use of or exposure to the product may cause temporary or medically reversible adverse health consequences, or where the probability of serious consequences is remote. The classification shown here comes from the FDA record.

Additional record details

Recall type: Voluntary: Firm initiated. Initial notification: Letter.

What to do next

If you believe you have the recalled product, use the recall number and firm information above to confirm the official notice and follow the instructions issued by the FDA, recalling firm, retailer or product manufacturer. For drugs and medical devices, decisions about treatment or medical care should be discussed with a qualified health professional.

About this record

Recall Lookup USA preserves the most complete source information successfully retrieved. We do not create missing facts or infer affected lots or VINs. The official record may still change, so use the identifier above when verifying current instructions.

FDA source limitation: openFDA enforcement reports are a reference dataset, not a live public-alert or recall-lifecycle service. FDA notes that enforcement-report status may not be updated after classification. Confirm current actions with the FDA, recalling firm or appropriate healthcare professional when relevant.

Related recall records

Other records from the same recalling company are shown first when available.