Trocar manufactured with the shaft too long and does not meet manufacturing specifications. As a result, when used with the 30 neuroendoscope, a portion of the visual field is obscured.
Potential for the spring to become loose and fall out of the device, if the spring falls out during a surgical procedure, it may enter the patient's body.
Insufficient clamping force of the cross connectors in the spinal surgical system which may lead to movement of the connectors on the rods and/or microparticle abrasion.
Class IIFDA: TerminatedAesculap Implant Systems LLC
Insufficient clamping force of the cross connectors in the spinal surgical system which may lead to movement of the connectors on the rods and/or microparticle abrasion.
Class IIFDA: TerminatedAesculap Implant Systems LLC
Insufficient clamping force of the cross connectors in the spinal surgical system which may lead to movement of the connectors on the rods and/or microparticle abrasion.
Class IIFDA: TerminatedAesculap Implant Systems LLC
Insufficient clamping force of the cross connectors in the spinal surgical system which may lead to movement of the connectors on the rods and/or microparticle abrasion.
Class IIFDA: TerminatedAesculap Implant Systems LLC
Fracture or breakage of the spinal fixation arm at the downtube instrument if the 90 degree angle is not met when using the removal key with the spinal fixation system.
Class IIFDA: TerminatedAesculap Implant Systems LLC
Fracture or breakage of the spinal fixation arm at the downtube instrument if the 90 degree angle is not met when using the removal key with the spinal fixation system. Redesign of removal…
Class IIFDA: TerminatedAesculap Implant Systems LLC
Insufficient clamping force of the cross connectors in the spinal surgical system which may lead to movement of the connectors on the rods and/or microparticle abrasion.
Class IIFDA: TerminatedAesculap Implant Systems LLC
Insufficient clamping force of the cross connectors in the spinal surgical system which may lead to movement of the connectors on the rods and/or microparticle abrasion.
Class IIFDA: TerminatedAesculap Implant Systems LLC
Malfuncton-Implant did not deploy successfully may necessitate the need for an additional medical intervention for patients which would result in a potential delay in surgery
Class IIFDA: TerminatedAesculap Implant Systems LLC
Malfuncton-Implant did not deploy successfully may necessitate the need for an additional medical intervention for patients which would result in a potential delay in surgery
Class IIFDA: TerminatedAesculap Implant Systems LLC
Malfunction- loosening of the implant resulting in a potential revision surgery
Class IIFDA: TerminatedAesculap Implant Systems LLC
Understanding this recall history
This page summarizes recall records in which the official source identifies Aesculap Implant Systems LLC as the recalling firm or manufacturer. The number of records should not be treated as a safety rating or a measure of company size, because recall counts depend on product mix, reporting periods and how government records are organized.